Building your NDE Program

Chateau

  1. 1. You can mark as an NDE component by setting the NDE property field to YES.

    You can mark as an NDE component by setting the NDE property field to YES.
  2. 2. Select the dropdown to change from No to Yes

    Select the dropdown to change from No to Yes
  3. 3. Untitled Step

    Screenshot for step 3
    1. 4. A. Create a Query in the Component grid to allow you to call up all of your NDE components with a single query button.

    2. 4. B. Select NDE

    A. Create a Query in the Component grid to allow you to call up all of your NDE components with a single query button. B. Select NDE
  4. 5. Create a Query in the Component grid to allow you to call up all of your NDE components with a single query button.

    Ensure Yes is selected and save the query if desired
    1. 6. A. Fine-tune the layout of this NDE grid so you can have a ready report for your NDE components, with pre-selected fields for convenient export to Excel.

    2. 6. B. Select desired fields

    A. Fine-tune the layout of this NDE grid so you can have a ready report for your NDE components, with pre-selected fields for convenient export to Excel. B. Select desired fields
  5. 7. Use the NDE field in the Rules / Manage Rule Specs to set these components for special M21 monitoring frequency (such as Annual).

    Use the NDE field in the Rules / Manage Rule Specs to set these components for special M21 monitoring frequency (such as Annual).
  6. 8. Set the background adjustment to be applied only to NDE (and CVS) components. You do this by going to Settings / Miscellaneous and adjusting the background settings.

    Set the background adjustment to be applied only to NDE (and CVS) components. You do this by going to Settings / Miscellaneous and adjusting the background settings.
  7. 9. Trigger a message to be displayed to monitoring techs they have NDE components to be monitored and they should ensure to take a background upwind and downwind to comply with specific regulatory requirements. You do this in Field Events by toggling on NDE and CVS Background.

    Trigger a message to be displayed to monitoring techs they have NDE components to be monitored and they should ensure to take a background upwind and downwind to comply with specific regulatory requirements. You do this in Field Events by toggling on
    1. 10. A. Go to Settings / Chateau Mobile Fields and select NDE from the left list.

    2. 10. B. Select the > arrow to move it to the right list.

    3. 10. C. This will cause the NDE field to appear in Chateau Mobile.

    A. Go to Settings / Chateau Mobile Fields and select NDE from the left list. B. Select the > arrow to move it to the right list. C. This will cause the NDE field to appear in Chateau Mobile.
    1. 11. A. NDE now shows as an available field

    2. 11. B. You can rename the tab it appears on if desired

    A. NDE now shows as an available field B. You can rename the tab it appears on if desired
  8. 12. Turn on the >500 PPM on NDE in order to receive an immediate notification if and when an NDE component leaks with over 500 PPM. This will enable you to reassess whether the component should be considered an NDE.

    Turn on the >500 PPM on NDE in order to receive an immediate notification if and when an NDE component leaks with over 500 PPM. This will enable you to reassess whether the component should be considered an NDE.
  9. 13. Click on the tile to view any alerts.

    Click on the tile to view any alerts.